2   \label{sec:Grounding}
3   The grounding scheme followed during the TIB integration is scketched in Fig. \ref{fig:grounding},
4   for an more complete description see~\cite{ref:grounding}.
5 < The high and low voltage return lines are joined together at the mother cable head, then this
6 < point, for all the strings in the shell, is connect to a gold plated copper sheet fixed to the
5 > The high and low voltage return lines of each string
6 > are joined together at the mother cable head, then this
7 > point is connect to a gold plated copper sheet (called {\it corona}) fixed to the
8   shell front flange. This sheet has been introduced to have a better quality soldering connections
9 < with respect to the cooling manifolds but it is equipotential to them. \\
9 > with respect to the aluminum cooling manifolds but it is equipotential to them. \\
10   Other important ground connections are at the single module level. On the front-end hybrids
11   of all the single sided modules and on the R-Phi double sided ones, a small
12 < gold plated copper pin (called "cometa") is soldered on the low voltage common return,
12 > gold plated copper pin (called {\it cometa}) is soldered on the low voltage common return,
13   at the filtering capacitor level, and
14   it is forced in contact with the module carbon fiber frame. In such a way the module frame is
15 < properly grounded resulting in a flat, expecially for the first and last strip of
15 < each APV25, strip noise profile.
15 > properly grounded resulting in a flat strip noise profile.
16   Furthermore a connection has been done between the front-end hybrid return of end-flange side
17   module and the cooling pipe close to it.\\
18 < The DOHM return and its shielding have been also connected to the cooling manifolds. The DOHM
18 > The DOHM return and its shielding have been also connected to the {\it corona}. The DOHM
19   return is also in contact with the mother cable return via the control cable ground lines.
20  
21 < \begin{figure}
22 < \begin{center}
23 <  \includegraphics[width=0.85\textwidth]{Figs/grounding.pdf}
24 < \end{center}
25 < \caption{Scheme of the TIB shell grounding.}
26 < \label{fig:grounding}
27 < \end{figure}
21 > %\begin{figure}
22 > %\begin{center}
23 > %  \includegraphics[width=0.85\textwidth]{Figs/grounding.pdf}
24 > %\end{center}
25 > %\caption{Scheme of the TIB shell grounding.}
26 > %\label{fig:grounding}
27 > %\end{figure}
28  
29  
30   \begin{figure}