ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/TIBTIDNotes/TIBTIDIntNote/SiStripLayout.tex
(Generate patch)

Comparing UserCode/TIBTIDNotes/TIBTIDIntNote/SiStripLayout.tex (file contents):
Revision 1.1 by sguazz, Tue Jan 20 11:13:35 2009 UTC vs.
Revision 1.6 by carlo, Wed May 20 15:56:13 2009 UTC

# Line 1 | Line 1
1 < \section{The Silicon Strip Tracker Layout}
2 < \label{sec:Layout}
3 < The CMS SST
4 < instruments the radial range between 20~cm and 116~cm and $|\eta| < 2.5$ around the
5 < LHC interaction point.
6 < The central region ($|z| < 118$ cm
7 < \footnote{A CMS coordinate system, used through this note, is defined in such a way that
8 < $z$ is the coordinate along the LHC beam axis, $y$ is the vertical direction and $x$
9 < complete the system; the origin being the nominal beam interaction point.})
10 < is split into an Inner Barrel (TIB), made of four detector layers, and an
11 < Outer Barrel (TOB), made of six detector layers. The TIB is shorter than the TOB, and is
12 < complemented
13 < by three Inner Disks per side (TID), each Disk being in turn composed of three
14 < Rings. The forward and backward regions
15 < (124~cm $ < |z| < $282~cm) are covered by nine Endcap (TEC) disks per side, each one made of
16 < up to seven rings.
17 < The two innermost layers of both TIB and TOB as well as rings number one, two and five
18 < of TEC and one and two of TID are instrumented with double-sided detector modules.
19 < A complete description of the Silicon Tracker layout (Fig.\ref{fig:layout})  
20 < can be found elsewhere~\cite{ref:layout}.\\
1 > \section{TIB and TID layout}
2 >
3 > TIB and TID are very compact objects with high readout granularity;
4 > channel and module densities are three to four times larger than in
5 > the other SST subsystems (Table~\ref{table:Density}).
6 > The TIB and TID layout has been designed keeping in mind their complexity:
7 > the mechanical structures have been simplified as much as possible,
8 > while the routing of the services (cooling, readout, controls) has been
9 > adapted to the very high channel density making use of all accessible
10 > paths inside the detector.
11 >
12 > %matching the
13 > %following features: simple mechanical structure; easy routing of the
14 > %large number of service connections (cooling, readout, controls); easy
15 > %component mounting in the case of the TIB non-planar (cylindrical)
16 > %geometry; optimization the theta (and phi?) for the TID.
17 >
18 > The TIB is structured in four concentric layers. Each layer is
19 > split along the vertical plane at $z=0$ into two almost identical half-layers. Each
20 > half-layer is further split along the horizontal at $y=0$ into two semi-cylindrical
21 > structures, also referred to as ``shells''.
22 > Both spilts in $\phi$ and $z$ are done ins such a way that the sensor surfaces always
23 > overlap leaving no dead area when measuring high momentum charged particles coming
24 > from the interaction region.
25 > The shell structure is a
26 > semi-cylindrical carbon fiber assembly strenghten by two circular
27 > flanges at both ends. To decrease their density and to provide a better accessibility
28 > during integration, modules and services are hold
29 > either on the external and the internal surfaces. The services are laid down on
30 > the surface and run parallel to the $z$ axis.
31 > % on the surface toward the end (i.e. in the
32 > %direction along which $|z|$ increases).
33 > The modules and the related
34 > services that sit on the same side of a shell at the same $\phi$
35 > coordinate constitute a \textit{string}.
36 >
37 > The TID is split into six disks (three per each side of
38 > TIB). The disk is made up by three sub-disks called "rings" since each
39 > ring holds modules at the same radius. The ring structure consists of
40 > a mechanical support made of an annular carbon fiber honeycomb.
41 > Also in this case modules and services are located on both sides
42 > of the mechanical structure.
43 > %to decrease the density
44 > %and therefore providing a better accessibility during ring integration
45 > %and  disk assembly.
46 >
47 > The TIB/TID system is physically
48 > divided into two separated structures, one located in the
49 > $z > 0$ region and one located in the $z < 0$ region and known as
50 > TIB/TID+ and TIB/TID- respectively. Each TID+ and TID- is obtained by
51 > inserting, positioning and fixing the three disks into a carbon fiber
52 > cylinder called {\it Service Cylinder}. Each Service Cylinder has
53 > several holes at the disk positions; this allow the
54 > connection of the power lines and to route out all the fibers of the
55 > disk. The Service Cylinder is also used to connect mechanically TIB+/-
56 > and TID+/-, and to route out the services of the TIB and of the TID.
57 >
58 > The cooling in the TIB/TID is distributed via aluminum pipe circuits  
59 > that  are bent into loops and soldered to inlet/outlet manifolds at
60 > the flange for the TIB, and at the ring outer edge for the TID.
61 > The thermal connection between pipes and sensor modules is made with aluminum ledges which are
62 > precisely glued on the carbon fiber support structure and in good thermal contact with the pipes.
63 > On each ledge there are two threaded M1 holes onto which the modules are tightened.
64 > Precisely drilled slots, coaxial with the threaded holes, are the reference point where
65 > inserts are stick in providing mechanical reference for modules. An example for a TIB module
66 > is shown in Fig.~\ref{fig:module_cooling}).
67 >
68 > The TIB and TID substructures, 16 shells and 18 rings, are relatively
69 > large-sized objects: one shell holds 135 to 216 modules, one ring holds 40 to 48 modules.
70 > Some other relevant specifications of the TIB and TID substructures are
71 > summarized in Table~\ref{table:layers}.
72 > A finished half of the TIB and a TID Disk are shown in
73 > Fig.~\ref{fig:tib} and~\ref{fig:tid}.
74 > %The pictures allow the sub-structures to be recognized.
75 >
76 >
77 >
78   \begin{figure}[!htb]
79   \begin{center}
80 <  \includegraphics[width=0.85\textwidth]{Figs/rz.pdf}
80 >  \includegraphics[width=0.45\textwidth]{Figs/shell.pdf}
81 > %  \includegraphics[height=0.5\textwidth]{Figs/TIB-assembled.pdf}
82 >  \hskip 1cm
83 >  \includegraphics[width=0.45\textwidth]{Figs/TIB_barrel.png}
84   \end{center}
85 < \caption{Longitudinal cross section of one quarter of the CMS SST.
86 < Thicker (blue) segments indicate double-sided silicon microstrip modules.
87 < The nominal beam interaction point is located in (0,0), dimensions are in mm.
88 < The pseudorapidity ($\eta$) coverage is also shown.}
89 < \label{fig:layout}       % Give a unique label
85 > \caption{A layer 3 TIB shell (left panel) and half of TIB assembled (right panel).}
86 > \label{fig:tib}       % Give a unique label
87 > \end{figure}
88 >
89 > \begin{figure}[!htb]
90 > \begin{center}
91 >  \includegraphics[height=0.35\textwidth]{Figs/ring.pdf}
92 > %  \includegraphics[height=0.5\textwidth]{Figs/TIB-assembled.pdf}
93 >  \hskip 3cm
94 >  \includegraphics[height=0.35\textwidth]{Figs/TID-disk.pdf}
95 > \end{center}
96 > \caption{A TID ring 1 assembled (left panel) and one complete TID disk (right panel).}
97 > \label{fig:tid}       % Give a unique label
98 > \end{figure}
99 >
100 >
101 > \begin{table}[!htb]
102 > \begin{center}
103 > %\begin{tabular}{|l||c|c|c|c|c|c|c|}
104 > \caption[smallcaption]{Total number of modules, strips (or electronic readout channels), detector volume and
105 > channel density for the different tracker subsystems. Service access area is also defined
106 > for barrel geometry detectors (TIB and TOB) as their flange area. The channel density in this
107 > area gives also an idea of the complexity of the detector integration.}
108 > \label{table:Density}
109 > \begin{tabular}{|l|ccccccc|}
110 > \hline
111 > &         &          &        & Module   & Channel                    & Service  & Service              \\
112 > & \# of   &\# of     & Volume & Density   & Density                    & Area & Density             \\
113 > & modules & channels & [m$^3$]& [$\times 10^3$  m$^{-3}$] & [$\times 10^6$ ch m$^{-3}$] & [m$^2$] &  [$\times 10^6$ ch m$^{-2}$]\\
114 > %\hline
115 > \hline
116 > TIB & 2724 & 1 787 904 & 0.82 & 3.2 &  2.2 & 1.6 & 1.11\\
117 > %\hline
118 > TID & 816 & 565 248 & 0.5 & 1.6  & 1.1  & & \\
119 > %\hline
120 > TOB & 5208 & 3 096 576 & 5.9 & 0.89  & 0.52 & 5.7 & 0.54\\
121 > %\hline
122 > TEC & 6400 & 3 866 624 & 11 & 0.58 & 0.35  & & \\
123 > \hline
124 > \end{tabular}
125 > \end{center}
126 > \end{table}
127 >
128 >
129 > \begin{table}[!htb]
130 > \begin{center}
131 > \caption[smallcaption]{Details on the different layers/rings of the TIB/TID. }
132 > \label{table:layers}
133 > %\begin{tabular}{|l||c|c|c|c|c|c|c|}
134 > \begin{tabular}{|l|ccccccc|}
135 > \hline
136 > Layer & \# mechanical & \# cooling  &  DS/SS & \# of modules  & \# of channels & \# Control & \# Mother  \\  
137 >       &   structures  &  circuits    &  layer &  total         & per module         &  Rings     &  Cables  \\
138 > \hline
139 > % \hline
140 > TIB L1  & 4 shells & 12 & DS & 672 & 768 & 24 & 112 \\
141 > TIB L2  & 4 shells & 16 & DS & 864 & 768 & 32 & 144 \\
142 > TIB L3  & 4 shells & 12 & SS & 540 & 512 & 12 & 180 \\
143 > TIB L4  & 4 shells & 16 & SS & 648 & 512 & 16 & 216 \\
144 > TID R1  & 6 rings  & 24 & DS & 288 & 768 & 12 & 48 \\
145 > TID R2  & 6 rings  & 24 & DS & 288 & 768 & 12 & 48 \\
146 > TID R3  & 6 rings  & 24 & SS & 240 & 512 & 12 & 48 \\
147 > \hline
148 > \end{tabular}
149 > \end{center}
150 > \end{table}
151 >
152 >
153 > %\subsection{Mechanical Structures}
154 >
155 > %A TIB shell is shown on Fig.~\ref{fig:tibshell}).
156 >
157 > %Each cooling loop hosts three modules placed in a straight row, which is called a
158 > %A string of modules is connected to the same CCU, thus forming a control branch.
159 >
160 > %\begin{figure}
161 > %\centering
162 > %\includegraphics[width=\textwidth]{   }
163 > %\caption{TIB shell: are visible the internal and external parts, the cooling pipes and the string}
164 > %\label{fig:tibshell}
165 > %\end{figure}
166 >
167 >
168 > %\begin{figure}
169 > %\centering
170 > %\includegraphics[width=\textwidth]{   }
171 > %\caption{TID ring }
172 > %\label{fig:tidring}
173 > %\end{figure}
174 >
175 >
176 >
177 > \begin{figure}
178 > \centering
179 > \includegraphics[width=0.6\textwidth]{Figs/module_cooling.pdf}
180 > \caption{Module Cooling.
181 > \textbf{Upper picture:} part of a cooling loop with six ledges to hold three modules and three
182 > smaller ledges to hold Analog Opto-Hybrids (adjacent cooling circuits are partially visible).
183 > \textbf{Lower picture:} a detail of a cooling loop. The cooling fluid direction
184 > is evidenced with blue arrows, and the precision holes for module insertion are circled in
185 > red. A module mounted on the nearby position is also visible.}
186 > \label{fig:module_cooling}
187   \end{figure}
31 The whole tracker region is embedded into the CMS 4~Tesla solenoidal magnetic field.
32 Charged particle transverse momentum resolution of about 1.5\% for centrally-produced
33 muon of 100~GeV/$c$ is expected~\cite{ref:ptdr}. \\
34 From the detector construction point of view it is important to note that the TIB/TID
35 system is divided into two physically separated structures: TIB/TID+, which is located in the
36 $|z| > 0$ region and TIB/TID-, located in the $|z| < 0$.\\
37 The entire tracker is inserted in a carbon fiber Support Tube which is attached to
38 the Electromagnetic Calorimeter and insulated by the rest of the experiment by a
39 'Thermal Shield'.

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines