ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/Vuko/Notes/WZCSA07/AppendixFitTest.tex
(Generate patch)

Comparing UserCode/Vuko/Notes/WZCSA07/AppendixFitTest.tex (file contents):
Revision 1.1 by beaucero, Fri Jul 25 18:56:31 2008 UTC vs.
Revision 1.4 by beaucero, Sun Jul 27 17:53:05 2008 UTC

# Line 1 | Line 1
1 + \clearpage
2 + \newpage
3   \appendix
4   \section{Additional Cross Check on Background Estimation Studies}
5  
# Line 5 | Line 7 | In figures~\ref{fig:AllFits}, the fit ap
7   mass of \Z boson candidate is shown for each channel and for loose and
8   tight criteria. The fit is performed using an addition of a
9   convolution of a Gaussian and Breit-Wigner function and a line in
10 < order to fit the background.
10 > order to fit the background. It has to be noticed that due to a lack
11 > of statistics in chowder soup, all bin with 0 events from chowder have
12 > been modified in order to avoid to have an error at 0. The
13 > corresponding error in the bin with no event correspond to the weight
14 > of each process in Chowder soup. One can see that the errors are
15 > large, and the fit is then not really constraint.
16  
17  
18   \begin{figure}[hbt]
# Line 30 | Line 37 | The comparison can be seen in table~\ref
37                      & \multicolumn{2}{c|}{Background with genuine \Z} & \multicolumn{4}{c|}{Background without
38                      genuine \Z boson} \\
39   Channel    & $\Z+jets$ & $\Z b\bar{b}$ &   $t\bar{t}$ & $\W+jets$ & $t\bar{t}$ + $\W+jets$ & Fit result \\ \hline
40 < $3e$ Loose & 7.1 & 2.8 & 1.1 & 0.4 & 1.5& 4.3 $\pm$ 1.8 \\ \hline
41 < $3e$ Tight & 1.9 & 1.2 & 0.6 & 0.4 & 1.0 & 3.2 $\pm$ 1.5 \\ \hline  
42 < $2e1\mu$ Loose  & 4.0 & 4.7 & 5.3 & 0.0 & 5.3 & 17.3 $\pm$ 3.8\\ \hline
43 < $2e1\mu$ Tight  & 0.0 & 0.1 & 0.6 & 0.0 & 0.6 & 2.8 $\pm$ 1.6\\ \hline
44 < $2\mu 1e$ Loose & 10.0 & 2.8 & 0.8 & 0.0 & 0.8 & 4.6 $\pm$ 1.9\\ \hline
45 < $2\mu 1e$ Tight & 1.8 & 1.2 & 0.6 & 0.0 & 0.6 & 3.1 $\pm$ 1.5\\ \hline
46 < $3\mu$ Loose & 4.7 & 4.1 & 5.4 & 0.0 & 5.4 & 8.8 $\pm$ 2.8\\ \hline
47 < $3\mu$ Tight & 0.1 & 0.3 & 0.3 & 0.0 & 0.3 & 1.4 $\pm$ 1.2\\ \hline
40 > $3e$ Loose &2.8 & 2.9 & 0.8 & 0.1 & 0.9 & 1.0$ \pm $2.7 \\\hline
41 > $3e$ Tight &0.8 & 1.2 & 0.4 & 0.1 & 0.5 & 0.7$ \pm $2.5 \\\hline
42 > $2e1\mu$ Loose &1.3 & 4.7 & 4.5 & 0 & 4.5 & 4.2$ \pm $3.7 \\\hline
43 > $2e1\mu$ Tight &0.0 & 0.1 & 0.5 & 0 & 0.5 & 0.6$ \pm $2.5 \\\hline
44 > $2\mu1e$ Loose &4.1 & 2.9 & 0.5 & 0 & 0.5 & 0.9$ \pm $2.7 \\\hline
45 > $2\mu1e$ Tight &0.8 & 1.3 & 0.4 & 0 & 0.4 & 0.6$ \pm $2.4 \\\hline
46 > $3\mu$ Loose &1.9 & 4.2 & 4.1 & 0 & 4.1 & 2.3$ \pm $3.3 \\\hline
47 > $3\mu$ Tight &0.1 & 0.3 & 0.2 & 0 & 0.2 & 0.4$ \pm $2.4 \\\hline
48   \end{tabular}
49   \end{center}
50   \caption{Comparison between Monte Carlo truth information and the results of the fit for the background without genuine \Z boson. Number of events are obtained in the invariant mass range between 81 and 101 GeV. The ``Loose'' and ``Tight'' selection criteria applied for third lepton considered.
44 %I AM NOT SURE I UNDERSTAND WHAT IS WRITTEN HERE
45 % One has to consider that this study as been perform on a smaller sample than the other part of the analysis a 10\% statistics error as to be counted until the study is performed on the whole samples.
51   }
52   \label{tab:CompFit}
53   \end{table}
54  
55  
56   Nevertheless in association with the matrix method the background is
57 < well estimated as one can see in table~\ref{tab:FinalXC}.
57 > well estimated as one can see in table~\ref{tab:FinalXC}.The corresponding figure can be
58 > seen~\ref{fig:FinalMatrix3e}~\ref{fig:FinalMatrix2e1mu}~\ref{fig:FinalMatrix2mu1e}~\ref{fig:FinalMatrix3mu}
59 > for $3e$, $2e1\mu$, $2\mu1e$ and $3\mu$ channels respectively.
60  
61   \begin{table}[h]
62    \begin{center}
# Line 58 | Line 65 | well estimated as one can see in table~\
65   %$N_{Loose}$ - ZZ -Zgamma &19.7$\pm$1.1 &22.9$\pm$0.7 &22.9$\pm$1.1 &25.6$\pm$0.8 \\
66   %$N_{Loose} ^{non genuine Z}$ (Fit) &1.0$\pm$1.5  &11.2$\pm$5.5 &3.1$\pm$2.4 &  4.8$\pm$3.7\\
67   $N$ - ZZ -Zgamma &12.2$\pm$1.1 &8.7$\pm$0.6 &12.8$\pm$1.0 &11.1$\pm$0.7\\
68 < $N^{non genuine Z}$ (Fit)&3.2$\pm$1.5 &2.8$\pm$1.6 &3.1$\pm$1.5 &1.4$\pm$1.2\\
69 < $N^{genuine Z}$ (matrix method)& 2.8$\pm$1.5 &0.4$\pm$1.1 &4.2$\pm$1.7 &3.7$\pm$1.7\\\hline
70 < $N^{WZ}$ & 6.2$\pm$2.4 &5.5$\pm$2.0 &5.5$\pm$2.5 &6.0$\pm$2.2\\\hline
68 > $N^{non genuine Z}$ (Fit)&0.7$\pm$2.5 &0.6$\pm$2.5 &0.6$\pm$2.4 &0.4$\pm$2.4\\
69 > $N^{genuine Z}$ (matrix method)& 3.2$\pm$1.8 &0.7$\pm$0.9 &4.6$\pm$2.1 &0.9$\pm$1.1\\\hline
70 > $N^{WZ}$ & 8.3$\pm$3.2 &7.4$\pm$2.8 &7.6$\pm$3.3 &9.8$\pm$2.7\\\hline
71   \WZ from MC &7.9&8.0& 8.9 &10.1\\
72  
73   \hline
# Line 72 | Line 79 | $N^{WZ}$ & 6.2$\pm$2.4 &5.5$\pm$2.0 &5.5
79   \end{center}
80   \end{table}
81  
82 + \begin{figure}[hbt]
83 +  \begin{center}
84 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod3eLooseTightZmassMWtCut.eps}}
85 +  \caption{Result of Matrix Method application for $3e$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
86 +  \label{fig:FinalMatrix3e}
87 +  \end{center}
88 + \end{figure}
89 +
90 + \begin{figure}[hbt]
91 +  \begin{center}
92 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod2e1muLooseTightZmassMWtCut.eps}}
93 +  \caption{Result of Matrix Method application for $2e1\mu$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
94 +  \label{fig:FinalMatrix2e1mu}
95 +  \end{center}
96 + \end{figure}
97 +
98 + \begin{figure}[hbt]
99 +  \begin{center}
100 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod2mu1eLooseTightZmassMWtCut.eps}}
101 +  \caption{Result of Matrix Method application for $2\mu1e$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
102 +  \label{fig:FinalMatrix2mu1e}
103 +  \end{center}
104 + \end{figure}
105 +
106 + \begin{figure}[hbt]
107 +  \begin{center}
108 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod3muLooseTightZmassMWtCut.eps}}
109 +  \caption{Result of Matrix Method application for $3\mu$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
110 +  \label{fig:FinalMatrix3mu}
111 +  \end{center}
112 + \end{figure}
113 +
114 +
115 +
116 + Check on Without MWtCut Samples~\ref{tab:FitNoMWt} (Linear Fit):
117 + \begin{table}[h]
118 + \begin{center}
119 + \begin{tabular}{|l|c|c|c|c|c|c|c|} \hline
120 +                    & \multicolumn{2}{c|}{Background with genuine \Z} & \multicolumn{4}{c|}{Background without
121 +                    genuine \Z boson} \\
122 + Channel    & $\Z+jets$ & $\Z b\bar{b}$ &   $t\bar{t}$ & $\W+jets$ & $t\bar{t}$ + $\W+jets$ & Fit result \\ \hline
123 + $3e$ Loose &16.4 & 12.7 & 1.1 & 0.1 & 1.2 & 2.8$ \pm $3.4 \\\hline
124 + $3e$ Tight &4.9 & 5.0 & 0.5 & 0.1 & 0.7 & 1.7$ \pm $2.9 \\\hline
125 + $2e1\mu$ Loose &15.8 & 78.9 & 9.0 & 0 & 9.0 & 11.6$ \pm $4.9 \\\hline
126 + $2e1\mu$ Tight &0.3 & 2.0 & 0.7 & 0 & 0.7 & 1.0$ \pm $2.8 \\\hline
127 + $2\mu1e$ Loose &20.4 & 15.4 & 1.3 & 0 & 1.3 & 2.9$ \pm $3.5 \\\hline
128 + $2\mu1e$ Tight &5.8 & 5.6 & 0.5 & 0 & 0.5 & 1.7$ \pm $3.0 \\\hline
129 + $3\mu$ Loose &16.8 & 84.9 & 8.5 & 0 & 8.5 & 7.1$ \pm $4.4 \\\hline
130 + $3\mu$ Tight &0.3 & 2.3 & 0.2 & 0 & 0.2 & 0.7$ \pm $2.8 \\\hline
131 + \end{tabular}
132 + \end{center}
133 + \caption{Comparison between Monte Carlo truth information and the results of the fit for the background without genuine \Z boson. Number of events are obtained in the invariant mass range between 81 and 101 GeV. The ``Loose'' and ``Tight'' selection criteria applied for third lepton considered.
134 + %I AM NOT SURE I UNDERSTAND WHAT IS WRITTEN HERE
135 + % One has to consider that this study as been perform on a smaller sample than the other part of the analysis a 10\% statistics error as to be counted until the study is performed on the whole samples.
136 + }
137 + \label{tab:FitNoMWt}
138 + \end{table}
139 +
140 +
141 + In table~\ref{tab:FinalNoMWtCut}, the final results are presented if
142 + we remove the cut on the W transverse mass. Everthing is still in
143 + perfect agreement... The corresponding figure can be
144 + seen~\ref{fig:FinalMatrix3eNoWtCut}~\ref{fig:FinalMatrix2e1muNoWtCut}~\ref{fig:FinalMatrix2mu1eNoWtCut}~\ref{fig:FinalMatrix3muNoWtCut}
145 + for $3e$, $2e1\mu$, $2\mu1e$ and $3\mu$ channels respectively.
146 +
147 + \begin{table}[h]
148 +  \begin{center}
149 + \begin{tabular}{lcccc} \hline \hline
150 + & 3e &2e1$\mu$ &2$\mu$1e &3$\mu$\\ \hline
151 + %$N_{Loose}$ - ZZ -Zgamma &19.7$\pm$1.1 &22.9$\pm$0.7 &22.9$\pm$1.1 &25.6$\pm$0.8 \\
152 + %$N_{Loose} ^{non genuine Z}$ (Fit) &1.0$\pm$1.5  &11.2$\pm$5.5 &3.1$\pm$2.4 &  4.8$\pm$3.7\\
153 + $N$ - ZZ -Zgamma &21.9$\pm$5.4 &15.2$\pm$1.0 &24.9$\pm$4.4 &17.8$\pm$1.3\\
154 + $N^{non genuine Z}$ (Fit)&1.7$\pm$2.9 &1.0$\pm$2.8 &1.7$\pm$3.0 &0.7$\pm$2.8\\
155 + $N^{genuine Z}$ (matrix method)& 8.4$\pm$3.5 &5.7$\pm$4.7 &11.2$\pm$4.3 &6.4$\pm$5.3\\\hline
156 + $N^{WZ}$ & 11.8$\pm$7.0 &8.5$\pm$5.6 &12.0$\pm$6.8 &10.7$\pm$6.1\\\hline
157 + \WZ from MC &11.6&12.3& 13.1 &14.9\\
158 +
159 + \hline
160 + \end{tabular}
161 +
162 + \caption{Expected number of selected events for an integrated luminosity of 300
163 + pb$^{-1}$ for the signal and estimated background with 81 GeV $< M_Z < $ 101 GeV.}
164 + \label{tab:FinalNoMWtCut}
165 + \end{center}
166 + \end{table}
167 +
168 + \begin{figure}[hbt]
169 +  \begin{center}
170 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod3eLooseTightZmassNoCutMWt.eps}}
171 +  \caption{Before M$_T$(W) criteria: Result of Matrix Method application for $3e$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
172 +  \label{fig:FinalMatrix3eNoWtCut}
173 +  \end{center}
174 + \end{figure}
175 +
176 + \begin{figure}[hbt]
177 +  \begin{center}
178 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod2e1muLooseTightZmassNoCutMWt.eps}}
179 +  \caption{Before M$_T$(W) criteria: Result of Matrix Method application for $2e1\mu$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
180 +  \label{fig:FinalMatrix2e1muNoWtCut}
181 +  \end{center}
182 + \end{figure}
183 +
184 + \begin{figure}[hbt]
185 +  \begin{center}
186 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod2mu1eLooseTightZmassNoCutMWt.eps}}
187 +  \caption{Before M$_T$(W) criteria: Result of Matrix Method application for $2\mu1e$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
188 +  \label{fig:FinalMatrix2mu1eNoWtCut}
189 +  \end{center}
190 + \end{figure}
191 +
192 + \begin{figure}[hbt]
193 +  \begin{center}
194 +  \scalebox{0.8}{\includegraphics{figs/MatrixMethod3muLooseTightZmassNoCutMWt.eps}}
195 +  \caption{Before M$_T$(W) criteria: Result of Matrix Method application for $3\mu$ channel for Invariante mass of \Z boson candidate plot (a) and (c) when the lepton pass the loose criteria, (b) and (d) when the lepton pass the tight criteria. (a) and (b) represent the estimation of the background, (c) and (d) represent estimation of signal.}
196 +  \label{fig:FinalMatrix3muNoWtCut}
197 +  \end{center}
198 + \end{figure}
199 +
200 +
201 + TO BE REMOVE??? ONLY USEFUL FOR MUONS PART???
202 + Check on Loosy Samples~\ref{tab:FitLoosy} (Linear Fit):
203 + \begin{table}[h]
204 + \begin{center}
205 + \begin{tabular}{|l|c|c|c|c|c|c|c|} \hline
206 +                    & \multicolumn{2}{c|}{Background with genuine \Z} & \multicolumn{4}{c|}{Background without
207 +                    genuine \Z boson} \\
208 + Channel    & $\Z+jets$ & $\Z b\bar{b}$ &   $t\bar{t}$ & $\W+jets$ & $t\bar{t}$ + $\W+jets$ & Fit result \\ \hline
209 + $3e$ Loose &17.4 & 14.1 & 1.2 & 0.1 & 1.3 & 4.0$ \pm $3.6 \\\hline
210 + $3e$ Tight &5.3 & 5.8 & 0.7 & 0.1 & 0.8 & 2.7$ \pm $3.2 \\\hline
211 + $2e1\mu$ Loose &16.5 & 83.1 & 10.0 & 0 & 10.0 & 13.1$ \pm $5.0 \\\hline
212 + $2e1\mu$ Tight &0.3 & 2.0 & 1.0 & 0 & 1.0 & 1.3$ \pm $3.0 \\\hline
213 + $2\mu1e$ Loose &27.5 & 20.1 & 15.0 & 0.2 & 15.3 & 23.7$ \pm $5.5 \\ \hline
214 + $2\mu1e$ Tight &7.7 & 6.9 & 13.2 & 0.1 & 13.3 & 19.7$ \pm $5.2 \\ \hline
215 + $3\mu$ Loose &33.4 & 138.2 & 45.8 & 0.7 & 46.4 & 48.7$ \pm $6.7 \\\hline
216 + $3\mu$ Tight &8.9 & 25.2 & 19.7 & 0.2 & 19.9 & 23.5$ \pm $5.5 \\\hline
217 + \end{tabular}
218 + \end{center}
219 + \caption{Comparison between Monte Carlo truth information and the results of the fit for the background without genuine \Z boson. Number of events are obtained in the invariant mass range between 81 and 101 GeV. The ``Loose'' and ``Tight'' selection criteria applied for third lepton considered.
220 + %I AM NOT SURE I UNDERSTAND WHAT IS WRITTEN HERE
221 + % One has to consider that this study as been perform on a smaller sample than the other part of the analysis a 10\% statistics error as to be counted until the study is performed on the whole samples.
222 + }
223 + \label{tab:FitLoosy}
224 + \end{table}

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines