ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/benhoob/cmsnotes/ZMet2012/systematics.tex
(Generate patch)

Comparing UserCode/benhoob/cmsnotes/ZMet2012/systematics.tex (file contents):
Revision 1.1 by benhoob, Tue Feb 5 13:19:47 2013 UTC vs.
Revision 1.5 by benhoob, Fri May 31 08:24:49 2013 UTC

# Line 1 | Line 1
1   \clearpage
2  
3   \section{Systematic Uncertainties in Signal Acceptance}
4 + \label{sec:syst}
5  
6   In this section we discuss systematic uncertainties in the signal acceptance. These efficiency
7   uncertainties are relevant for the interpretations in the \wzmet\ and the GMSB models, which
# Line 16 | Line 17 | are combined with the results of the tri
17   Source & Value (\%) & Method \\
18   \hline
19   Luminosity & 4.4 & official CMS value \\
20 < Trigger efficiency & 3 & efficiency measurements documented in Sec. 4, Table 9 of AN-2012/248 \\
20 > Trigger efficiency & 5 & efficiency measurements documented in Sec. 4, Table 9 of AN-2012/248 \\
21   Lepton ID/isolation & 2 (per lepton) & Z tag-and-probe measurements in AN-2012/257 \\
22   B-veto & 6 & dedicated measurement in AN-2012/248 Sec. 7.6 \\
23   Z mass window requirement & 3 & see text and Table~\ref{tab:mllsyst} \\
# Line 28 | Line 29 | Jet selection, dijet mass, \MET & assess
29   \end{table}
30  
31   A summary of the efficiency uncertainties is presented in Table~\ref{tab:syst}.
32 < The CMS uncertainty in the luminosity is 4.4\%. The trigger efficiency is measured in AN-2102/248 with an uncertainty of 3\%.
32 > The CMS uncertainty in the luminosity is 4.4\%. The trigger efficiency is measured in AN-2102/248 with an uncertainty of 5\%.
33   The lepton identification and isolation requirements are measured in data and MC and found to be consistent within 2\%, for
34   the \pt\ $>$ 20 GeV region relevant for this analysis, in AN-2012/257. The impact of the b-veto on the signal acceptance
35   is quantified with a dedicated measurement performed in Sec. 7.6 of AN-2012/248. The uncertainty in the selection of dilepton
# Line 56 | Line 57 | mass windows of 60--120 GeV and 81-101 G
57   \hline
58   & ee & $\mu\mu$ \\
59   \hline
60 < MC loose & 200694.0 & 285462.5 \\
61 < MC tight & 183326.2 & 260960.0 \\  
60 > MC loose & 190661.9 & 238969.2 \\
61 > MC tight & 174162.5 & 218462.9 \\  
62   MC tight/loose & 0.913 $\pm$ 0.005 & 0.914 $\pm$ 0.004 \\
63   \hline
64   data loose & 209540 & 263747 \\

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines