ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C
(Generate patch)

Comparing UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C (file contents):
Revision 1.25 by fronga, Mon Aug 8 14:10:25 2011 UTC vs.
Revision 1.41 by buchmann, Wed Sep 28 15:19:00 2011 UTC

# Line 13 | Line 13 | using namespace std;
13  
14  
15   namespace PlottingSetup {
16 <  float luminosity=1078;//751.0;//486.0;//468.0//336.;//pb^{-1}
17 <  float lumiuncert=0.04;// to be indicated in [0,1] range, e.g. for 4% write 0.04
16 >
17 >  string directoryname="official_2096_golden_run_PAS_v4andon";
18 >  
19 >  bool RestrictToMassPeak=true; // at the moment setting this to false will only trigger alarms all over the place, but the idea is to be able to switch between
20 >                                // the regular on-peak JZB method and an off-peak opposite sign analysis
21 >  
22 >  float luminosity=2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
23 >  float lumiuncert=0.045;// to be indicated in [0,1] range, e.g. for 4% write 0.04
24 >
25    string jzbvariabledata="jzb[1]+0.06*pt";
26    string jzbvariablemc="jzb[1]+0.04*pt";
27    float jzbHigh = 350.; // Range for JZB plots
28 <  
28 >
29    samplecollection allsamples("completesamplecollection");
30    samplecollection signalsamples("signalsamplecollection");
31    samplecollection scansample("scansamplecollection");
32 +  samplecollection raresample("raresamplecollection");
33    int data=1;
34    int mc=0;
35    int mcwithsignal=2;
# Line 44 | Line 52 | namespace PlottingSetup {
52    //TCut basiccut("(passed_triggers||!is_data)");
53    
54    // SUSY scan parameters
47 //  float mglustart=25;float mgluend=1200;float mglustep=25; //guessed values for official file
48 //  float mLSPstart=25;float mLSPend=1200;float mLSPstep=25; //guessed values for official file
55    float mglustart=25;float mgluend=1200;float mglustep=25;
56    float mLSPstart=25;float mLSPend=1200;float mLSPstep=25;
57 +  
58 +  float m0start=20;  float m0end=2000;  float m0step=20;
59 +  float m12start=20; float m12end=760;  float m12step=20;
60  
61    
62    TCut essential(passtrig);//add here any cuts you ALWAYS want
# Line 60 | Line 69 | namespace PlottingSetup {
69    float fitresultconstdata=0;//this is the result when fitting in the 0-30 GeV range
70    float fitresultconstmc=0;//this is the result when fitting in the 0-30 GeV range
71    
72 <  int method=-1;
72 >  int method=-1;//Fitting method
73    
74    //now some style issues:
75    float DataMarkerSize=1.2;
# Line 81 | Line 90 | namespace PlottingSetup {
90    Double_t blue[5]  = { 0.51, 1.00, 0.12, 0.00, 0.00 };
91    int fi=TColor::CreateGradientColorTable(5, stops, red, green,blue, 255);
92    
93 +  // LIMITS
94 +  int nlimittoys=1000; // how many toys for setting limits
95 +  string limitmethod="cls";//what method to use to set limits
96    int limitpatience=50; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the grid.
97 +  bool ConsiderSignalContaminationForLimits=true; //whether or not to consider signal contamination when computing limits (standard:true)
98 +  int nuisancemodel=1;
99    
100 +  float JZBPeakPositionData=-999;
101 +  float JZBPeakPositionMC=-999;
102 +  float JZBPeakWidthData=-999;
103 +  float JZBPeakWidthMC=-999;
104 +
105 +  // two possible future systematics that ATM only take up CPU time in SUSY scans
106 +  bool computeJZBefficiency=false;
107 +  bool computeJZBresponse=false;
108 +
109 +  //watch out, the cbafbasedir string is in GeneralToolBox
110   }

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines