ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C
(Generate patch)

Comparing UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C (file contents):
Revision 1.30 by buchmann, Tue Aug 30 14:52:31 2011 UTC vs.
Revision 1.62 by buchmann, Thu Dec 8 16:07:51 2011 UTC

# Line 8 | Line 8
8   #include "SampleClass.C"
9   #endif
10   #define SetupLoaded
11 + #ifndef ResultLibraryClassLoaded
12 + #include "ResultLibraryClass.C"
13 + #endif
14 +
15  
16   using namespace std;
17  
18  
19   namespace PlottingSetup {
20 +
21 +  string directoryname="Results_With_4653ipb__Step7___UpdatedDatafile";
22    
23 <  string directoryname="Testing";
23 >  bool RestrictToMassPeak=true; //if you want to switch between offpeak ("false") and onpeak ("true") analysis please use this switch; the masscut below will be adapted automatically when adding samples :-)
24    
25 <  float luminosity=1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
26 <  float lumiuncert=0.04;// to be indicated in [0,1] range, e.g. for 4% write 0.04
25 >  float luminosity=4653.74;//p3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
26 > //  float luminosity=3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
27 > //  float luminosity=2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
28 >  float lumiuncert=0.045;// to be indicated in [0,1] range, e.g. for 4% write 0.04
29 >
30    string jzbvariabledata="jzb[1]+0.06*pt";
31    string jzbvariablemc="jzb[1]+0.04*pt";
32 <  float jzbHigh = 350.; // Range for JZB plots
33 <  
32 >  float jzbHigh = 400.; // Range for JZB plots
33 >
34    samplecollection allsamples("completesamplecollection");
35    samplecollection signalsamples("signalsamplecollection");
36 +  samplecollection systsamples("systematicssamplecollection");
37    samplecollection scansample("scansamplecollection");
38 +  samplecollection raresample("raresamplecollection");
39    int data=1;
40    int mc=0;
41    int mcwithsignal=2;
42    TCut passtrig("(passed_triggers||!is_data)");
43    TCut cutmass("abs(mll-91.2)<20");
44 +  TCut genMassCut("abs(genMll-91.2)<20");
45 +  TCut openmasscut("mll>40"); // this is the mass cut used in the off peak analysis!
46 +  TCut openGenmasscut("genMll>40");
47    //TCut cutmass("mll>2");
48    TCut basiccut("mll>2");//basically nothing.
49    TCut basicqualitycut("(pfJetGoodNum>=2&&pfJetGoodID[0]!=0)&&(pfJetGoodNum>=2&&pfJetGoodID[1]!=0)");//don't use this for the "essential cut", because we want to plot nJets as well as mll in the inclusive case; we thus use it as an addition nJets cut.
# Line 43 | Line 57 | namespace PlottingSetup {
57    TCut cutOSSF("(id1==id2)&&(ch1*ch2<0)");
58    TCut sidebandcut("(mll>55&&mll<70)||(mll>112&&mll<160)");
59  
46  //TCut sidebandcut("(mll>61&&mll<70)||(mll>112&&mll<190)");
47  //TCut basiccut("(passed_triggers||!is_data)");
48  
60    // SUSY scan parameters
50 //  float mglustart=25;float mgluend=1200;float mglustep=25; //guessed values for official file
51 //  float mLSPstart=25;float mLSPend=1200;float mLSPstep=25; //guessed values for official file
61    float mglustart=25;float mgluend=1200;float mglustep=25;
62    float mLSPstart=25;float mLSPend=1200;float mLSPstep=25;
54
63    
64 +  float m0start=20;  float m0end=2000;  float m0step=20;
65 +  float m12start=20; float m12end=760;  float m12step=20;
66 +  
67 +  int ScanXzones=15; // number of zones in x for (mSUGRA) scans
68 +  int ScanYzones=15; // number of zones in y for (mSUGRA) scans
69 +
70 +  //scan types:
71 +  int mSUGRA=1;
72 +  int SMS=2;
73 +  int GMSB=3;
74 +
75    TCut essential(passtrig);//add here any cuts you ALWAYS want
76    int dogaus=0;
77    int doKM=1;
# Line 63 | Line 82 | namespace PlottingSetup {
82    float fitresultconstdata=0;//this is the result when fitting in the 0-30 GeV range
83    float fitresultconstmc=0;//this is the result when fitting in the 0-30 GeV range
84    
85 <  int method=-1;
85 >  int method=-1;//Fitting method
86    
87    //now some style issues:
88    float DataMarkerSize=1.2;
# Line 73 | Line 92 | namespace PlottingSetup {
92    vector<float> Npred;
93    vector<float> Nprederr;
94    
95 +  //here we save our "flipped" number of predicted and observed events (with errors) -- this means that we consider JZB<-X as observed and construct the corresponding prediction
96 +  bool alwaysflip=false;
97 +  vector<float> flippedNobs;
98 +  vector<float> flippedNpred;
99 +  vector<float> flippedNprederr;
100 +  
101    int noJES=0;
102    int JESdown=1;
103    int JESup=2;
# Line 84 | Line 109 | namespace PlottingSetup {
109    Double_t blue[5]  = { 0.51, 1.00, 0.12, 0.00, 0.00 };
110    int fi=TColor::CreateGradientColorTable(5, stops, red, green,blue, 255);
111    
112 <  int limitpatience=50; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the grid.
113 <  bool ConsiderSignalContaminationForLimits=false; //whether or not to consider signal contamination when computing limits (standard:true)
112 >  // LIMITS
113 >  int nlimittoys=1000; // how many toys for setting limits
114 >  string limitmethod="cls";//what method to use to set limits
115 >  int limitpatience=15; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the t3 batch; the value for CRAB is on the next line
116 >  int limitpatienceCRAB=60;
117 >  bool ConsiderSignalContaminationForLimits=true; //whether or not to consider signal contamination when computing limits (standard:true)
118 >  int nuisancemodel=1;
119    
120    float JZBPeakPositionData=-999;
121    float JZBPeakPositionMC=-999;
122    float JZBPeakWidthData=-999;
123    float JZBPeakWidthMC=-999;
124 <  
124 >
125 >  // two possible future systematics that ATM only take up CPU time in SUSY scans
126 >  bool computeJZBefficiency=false;
127 >  bool computeJZBresponse=false;
128 >
129 >  bool requireZ=true;
130 >
131 >  string ScanSampleDirectory="SMS/"; // possibilities (atm) : SMS/, SMS_T5zzl/, GMSB/, mSUGRA/     note: this string needs to either contain "SMS", "GMSB", or "mSUGRA"
132 >
133 >  ResultLibrary allresults;
134   }

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines