ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C
(Generate patch)

Comparing UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C (file contents):
Revision 1.37 by buchmann, Wed Sep 7 14:25:55 2011 UTC vs.
Revision 1.47 by buchmann, Mon Nov 7 11:20:36 2011 UTC

# Line 14 | Line 14 | using namespace std;
14  
15   namespace PlottingSetup {
16  
17 <  string directoryname="official_2096";
18 <
19 <  float luminosity=2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
17 > //  string directoryname="official_2096ipb___forPASv5_withPDF";
18 >  string directoryname="official_3523ipb___forAN_prepaper_NewSelection";
19 >  
20 >  bool RestrictToMassPeak=true; //if you want to switch between offpeak ("false") and onpeak ("true") analysis please use this switch; the masscut below will be adapted automatically when adding samples :-)
21 >  
22 >  float luminosity=3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
23 > //  float luminosity=3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
24 > //  float luminosity=2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
25    float lumiuncert=0.045;// to be indicated in [0,1] range, e.g. for 4% write 0.04
26  
27    string jzbvariabledata="jzb[1]+0.06*pt";
# Line 26 | Line 31 | namespace PlottingSetup {
31    samplecollection allsamples("completesamplecollection");
32    samplecollection signalsamples("signalsamplecollection");
33    samplecollection scansample("scansamplecollection");
34 +  samplecollection raresample("raresamplecollection");
35    int data=1;
36    int mc=0;
37    int mcwithsignal=2;
38    TCut passtrig("(passed_triggers||!is_data)");
39    TCut cutmass("abs(mll-91.2)<20");
40 +  TCut genMassCut("abs(genMll-91.2)<20");
41 +  TCut openmasscut("mll>40"); // this is the mass cut used in the off peak analysis!
42 +  TCut openGenmasscut("genMll>40");
43    //TCut cutmass("mll>2");
44    TCut basiccut("mll>2");//basically nothing.
45    TCut basicqualitycut("(pfJetGoodNum>=2&&pfJetGoodID[0]!=0)&&(pfJetGoodNum>=2&&pfJetGoodID[1]!=0)");//don't use this for the "essential cut", because we want to plot nJets as well as mll in the inclusive case; we thus use it as an addition nJets cut.
# Line 53 | Line 62 | namespace PlottingSetup {
62    
63    float m0start=20;  float m0end=2000;  float m0step=20;
64    float m12start=20; float m12end=760;  float m12step=20;
56
65    
66 +  int ScanXzones=10; // number of zones in x for (mSUGRA) scans
67 +  int ScanYzones=10; // number of zones in y for (mSUGRA) scans
68 +
69    TCut essential(passtrig);//add here any cuts you ALWAYS want
70    int dogaus=0;
71    int doKM=1;
# Line 75 | Line 86 | namespace PlottingSetup {
86    vector<float> Npred;
87    vector<float> Nprederr;
88    
89 +  //here we save our "flipped" number of predicted and observed events (with errors) -- this means that we consider JZB<-X as observed and construct the corresponding prediction
90 +  vector<float> flippedNobs;
91 +  vector<float> flippedNpred;
92 +  vector<float> flippedNprederr;
93 +  
94    int noJES=0;
95    int JESdown=1;
96    int JESup=2;
# Line 88 | Line 104 | namespace PlottingSetup {
104    
105    // LIMITS
106    int nlimittoys=1000; // how many toys for setting limits
107 <  string limitmethod="bayesian";//what method to use to set limits
108 <  int limitpatience=50; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the grid.
107 >  string limitmethod="cls";//what method to use to set limits
108 >  int limitpatience=15; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the grid.
109    bool ConsiderSignalContaminationForLimits=true; //whether or not to consider signal contamination when computing limits (standard:true)
110    int nuisancemodel=1;
111    
# Line 98 | Line 114 | namespace PlottingSetup {
114    float JZBPeakWidthData=-999;
115    float JZBPeakWidthMC=-999;
116  
117 +  // two possible future systematics that ATM only take up CPU time in SUSY scans
118 +  bool computeJZBefficiency=false;
119 +  bool computeJZBresponse=false;
120 +
121 +
122    //watch out, the cbafbasedir string is in GeneralToolBox
123   }

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines