ViewVC Help
View File | Revision Log | Show Annotations | Root Listing
root/cvsroot/UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C
(Generate patch)

Comparing UserCode/cbrown/AnalysisFramework/Plotting/Modules/Setup.C (file contents):
Revision 1.47 by buchmann, Mon Nov 7 11:20:36 2011 UTC vs.
Revision 1.59 by buchmann, Wed Nov 30 10:33:22 2011 UTC

# Line 8 | Line 8
8   #include "SampleClass.C"
9   #endif
10   #define SetupLoaded
11 + #ifndef ResultLibraryClassLoaded
12 + #include "ResultLibraryClass.C"
13 + #endif
14 +
15  
16   using namespace std;
17  
18  
19   namespace PlottingSetup {
20  
21 < //  string directoryname="official_2096ipb___forPASv5_withPDF";
18 <  string directoryname="official_3523ipb___forAN_prepaper_NewSelection";
21 >  string directoryname="Results_With_4653ipb__Step1";
22    
23    bool RestrictToMassPeak=true; //if you want to switch between offpeak ("false") and onpeak ("true") analysis please use this switch; the masscut below will be adapted automatically when adding samples :-)
24    
25 <  float luminosity=3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
25 >  float luminosity=4653.74;//p3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
26   //  float luminosity=3523.18;//2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
27   //  float luminosity=2096.0;//3172.73;//2096.0;//1936;//751.0;//486.0;//468.0//336.;//pb^{-1}
28    float lumiuncert=0.045;// to be indicated in [0,1] range, e.g. for 4% write 0.04
# Line 30 | Line 33 | namespace PlottingSetup {
33  
34    samplecollection allsamples("completesamplecollection");
35    samplecollection signalsamples("signalsamplecollection");
36 +  samplecollection systsamples("systematicssamplecollection");
37    samplecollection scansample("scansamplecollection");
38    samplecollection raresample("raresamplecollection");
39    int data=1;
# Line 53 | Line 57 | namespace PlottingSetup {
57    TCut cutOSSF("(id1==id2)&&(ch1*ch2<0)");
58    TCut sidebandcut("(mll>55&&mll<70)||(mll>112&&mll<160)");
59  
60 +  TCut Weight("weight"); // this is the weight that is used everywhere
61 +
62    //TCut sidebandcut("(mll>61&&mll<70)||(mll>112&&mll<190)");
63    //TCut basiccut("(passed_triggers||!is_data)");
64    
# Line 63 | Line 69 | namespace PlottingSetup {
69    float m0start=20;  float m0end=2000;  float m0step=20;
70    float m12start=20; float m12end=760;  float m12step=20;
71    
72 <  int ScanXzones=10; // number of zones in x for (mSUGRA) scans
73 <  int ScanYzones=10; // number of zones in y for (mSUGRA) scans
72 >  int ScanXzones=15; // number of zones in x for (mSUGRA) scans
73 >  int ScanYzones=15; // number of zones in y for (mSUGRA) scans
74 >
75 >  //scan types:
76 >  int mSUGRA=1;
77 >  int SMS=2;
78 >  int GMSB=3;
79  
80    TCut essential(passtrig);//add here any cuts you ALWAYS want
81    int dogaus=0;
# Line 87 | Line 98 | namespace PlottingSetup {
98    vector<float> Nprederr;
99    
100    //here we save our "flipped" number of predicted and observed events (with errors) -- this means that we consider JZB<-X as observed and construct the corresponding prediction
101 +  bool alwaysflip=false;
102    vector<float> flippedNobs;
103    vector<float> flippedNpred;
104    vector<float> flippedNprederr;
# Line 105 | Line 117 | namespace PlottingSetup {
117    // LIMITS
118    int nlimittoys=1000; // how many toys for setting limits
119    string limitmethod="cls";//what method to use to set limits
120 <  int limitpatience=15; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the grid.
120 >  int limitpatience=15; // for how many minutes should the limit calculation (for one configuration!) be allowed to run before being aborted? this only has an effect when when running on the t3 batch; the value for CRAB is on the next line
121 >  int limitpatienceCRAB=60;
122    bool ConsiderSignalContaminationForLimits=true; //whether or not to consider signal contamination when computing limits (standard:true)
123    int nuisancemodel=1;
124    
# Line 118 | Line 131 | namespace PlottingSetup {
131    bool computeJZBefficiency=false;
132    bool computeJZBresponse=false;
133  
134 +  bool requireZ=true;
135 +
136 +  string ScanSampleDirectory="GMSB/"; // possibilities (atm) : SMS/, SMS_T5zzl/, GMSB/, mSUGRA/     note: this string needs to either contain "SMS", "GMSB", or "mSUGRA"
137  
138 <  //watch out, the cbafbasedir string is in GeneralToolBox
138 >  ResultLibrary allresults;
139   }

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines