# | Line 55 | Line 55 | hcal, and tracker, in a cone of 0.3. | |
---|---|---|
55 | \item At least one of the hits from the | |
56 | standalone muon must be used in the global fit. | |
57 | ||
58 | < | \item {\color{red} Should we add a cut on the momentum error?} |
58 | > | \item Require tracker $\Delta P_T/P_T < 0.1$. This cut was not in the original top analysis. |
59 | > | It is motivated by the observation of |
60 | > | poorly measured muons in data with large |
61 | > | relative $P_T$ uncertainty, giving significant contributions to the \met. |
62 | > | |
63 | ||
64 | \end{itemize} | |
65 |
– | Removed lines |
+ | Added lines |
< | Changed lines |
> | Changed lines |