3 |
|
|
4 |
|
%{\bf \color{red} The numbers in this Section need to be double checked.} |
5 |
|
|
6 |
+ |
\subsection{Limit on number of events} |
7 |
+ |
\label{sec:limnumevents} |
8 |
|
As discussed in Section~\ref{sec:results}, we see one event |
9 |
|
in the signal region, defined as SumJetPt$>$300 GeV and |
10 |
|
\met/$\sqrt{\rm SumJetPt}>8.5$ GeV$^{\frac{1}{2}}$. |
24 |
|
and with the observation of one event in the signal region. |
25 |
|
We calculate a Bayesian 95\% CL upper limit\cite{ref:bayes.f} |
26 |
|
on the number of non SM events in the signal region to be 4.1. |
27 |
< |
We have also calculated this limit using a profile likelihood method |
28 |
< |
as implemented in the cl95cms software, and we also find 4.1. |
27 |
> |
We have also calculated this limit using |
28 |
> |
% a profile likelihood method |
29 |
> |
% as implemented in |
30 |
> |
the cl95cms software\cite{ref:cl95cms}, |
31 |
> |
and we also find 4.1. (This is not surprising, since cl95cms |
32 |
> |
also gives baysean upper limits with a flat prior). |
33 |
|
These limits were calculated using a background prediction of $N_{BG} = 1.4 \pm 0.8$ |
34 |
|
events, the error-weighted average of the ABCD and $P_T(\ell\ell)$ background |
35 |
|
predictions. The upper limit is not very sensitive to the choice of |
42 |
|
are from energy scale (Section~\ref{sec:systematics}), luminosity, |
43 |
|
and lepton efficiency. |
44 |
|
|
39 |
– |
We also performed a scan of the mSUGRA parameter space. We set $\tan\beta=10$, |
40 |
– |
sign of $\mu = +$, $A_{0}=0$~GeV, and scan the $m_{0}$ and $m_{1/2}$ parameters |
41 |
– |
in steps of 10~GeV. For each scan point, we exclude the point if the expected |
42 |
– |
yield in the signal region exceeds 4.7, which is the 95\% CL upper limit |
43 |
– |
based on an expected background of $N_{BG}=1.4 \pm 0.8$ and a 20\% acceptance |
44 |
– |
uncertainty. The results are shown in Fig.~\ref{fig:msugra}. |
45 |
– |
|
46 |
– |
\begin{figure}[tbh] |
47 |
– |
\begin{center} |
48 |
– |
\includegraphics[width=0.6\linewidth]{msugra.png} |
49 |
– |
\caption{\label{fig:msugra}\protect Exclusion curve in the mSUGRA parameter space, |
50 |
– |
assuming $\tan\beta=10$, sign of $\mu = +$ and $A_{0}=0$~GeVs.} |
51 |
– |
\end{center} |
52 |
– |
\end{figure} |
53 |
– |
|
45 |
|
|
46 |
+ |
\subsection{Outreach} |
47 |
+ |
\label{sec:outreach} |
48 |
|
Conveying additional useful information about the results of |
49 |
|
a generic ``signature-based'' search such as the one described |
50 |
< |
in this note is a difficult issue. The next paragraph represent |
51 |
< |
our attempt at doing so. |
50 |
> |
in this note is a difficult issue. |
51 |
> |
Here we attempt to present our result in the most general |
52 |
> |
way. |
53 |
|
|
54 |
< |
Other models of new physics in the dilepton final state |
54 |
> |
Models of new physics in the dilepton final state |
55 |
|
can be confronted in an approximate way by simple |
56 |
|
generator-level studies that |
57 |
|
compare the expected number of events in 34.0~pb$^{-1}$ |
59 |
|
of such studies are the kinematical cuts described |
60 |
|
in this note, the lepton efficiencies, and the detector |
61 |
|
responses for SumJetPt and \met/$\sqrt{\rm SumJetPt}$. |
68 |
– |
{LOOKING AT THE 38X MC PLOTS BY EYE, THE FOLLOWING QUANTITIES LOOK ABOUT RIGHT.} |
62 |
|
The muon identification efficiency is $\approx 95\%$; |
63 |
|
the electron identification efficiency varies from $\approx$ 63\% at |
64 |
|
$P_T = 10$ GeV to 91\% for $P_T > 30$ GeV. The isolation |
65 |
|
efficiency in top events varies from $\approx 83\%$ (muons) |
66 |
|
and $\approx 89\%$ (electrons) at $P_T=10$ GeV to |
67 |
< |
$\approx 95\%$ for $P_T>60$ GeV. {\bf \color{red} The following quantities were calculated |
68 |
< |
with Spring10 samples. } The average detector |
67 |
> |
$\approx 95\%$ for $P_T>60$ GeV. |
68 |
> |
%{\bf \color{red} The following numbers were derived from Fall 10 samples. } |
69 |
> |
The average detector |
70 |
|
responses for SumJetPt and $\met/\sqrt{\rm SumJetPt}$ are |
71 |
< |
$1.00 \pm 0.05$ and $0.94 \pm 0.05$ respectively, where |
71 |
> |
$1.02 \pm 0.05$ and $0.94 \pm 0.05$ respectively, where |
72 |
|
the uncertainties are from the jet energy scale uncertainty. |
73 |
< |
The experimental resolutions on these quantities are 10\% and |
74 |
< |
14\% respectively. |
73 |
> |
The experimental resolutions on these quantities are 11\% and |
74 |
> |
16\% respectively. |
75 |
|
|
76 |
|
To justify the statements in the previous paragraph |
77 |
|
about the detector responses, we plot |
81 |
|
signal region. |
82 |
|
% (SumJetPt $>$ 300 GeV and \met/$\sqrt{\rm SumJetPt} > 8.5$ |
83 |
|
% Gev$^{\frac{1}{2}}$). |
84 |
< |
{\bf \color{red} The following numbers were derived from Spring10 samples, They should be the same for the Fall10 samples; this needs to be verified .} |
84 |
> |
%{\bf \color{red} The following numbers were derived from Fall10 samples } |
85 |
|
We find that the average SumJetPt response |
86 |
< |
in the Monte Carlo is very close to one, with an RMS of order 10\% while |
86 |
> |
in the Monte Carlo is about 1.02, with an RMS of order 11\% while |
87 |
|
the response of \met/$\sqrt{\rm SumJetPt}$ is approximately 0.94 with an |
88 |
< |
RMS of 14\%. |
88 |
> |
RMS of 16\%. |
89 |
|
|
90 |
|
%Using this information as well as the kinematical |
91 |
|
%cuts described in Section~\ref{sec:eventSel} and the lepton efficiencies |
108 |
|
to the true quantity in MC. These plots are done using the LM0 |
109 |
|
Monte Carlo, but they are not expected to depend strongly on |
110 |
|
the underlying physics. |
111 |
< |
{\bf \color{red} These plots were made with Fall10 samples. } } |
111 |
> |
%{\bf \color{red} These plots were made with Fall10 samples. } |
112 |
> |
} |
113 |
|
\end{center} |
114 |
|
\end{figure} |
115 |
|
|
146 |
|
% 1 29.995 0.50457E-06 |
147 |
|
% |
148 |
|
% limit: less than 4.689 signal events |
149 |
+ |
|
150 |
+ |
|
151 |
+ |
\subsection{mSUGRA scan} |
152 |
+ |
\label{sec:mSUGRA} |
153 |
+ |
We also perform a scan of the mSUGRA parameter space, as recomended |
154 |
+ |
by the SUSY group convenors\cite{ref:scan}. |
155 |
+ |
The goal of the scan is to determine an exclusion region in the |
156 |
+ |
$m_0$ vs. $m_{1/2}$ plane for |
157 |
+ |
$\tan\beta=3$, |
158 |
+ |
sign of $\mu = +$, and $A_{0}=0$~GeV. This scan is based on events |
159 |
+ |
generated with FastSim. |
160 |
+ |
|
161 |
+ |
The first order of business is to verify that results using |
162 |
+ |
Fastsim and Fullsim are compatible. To this end we compare the |
163 |
+ |
expected yield for the LM1 point in FullSim (3.56 $\pm$ 0.06) and |
164 |
+ |
FastSim (3.29 $\pm$ 0.27), where the uncertainties are statistical only. |
165 |
+ |
These two numbers are in agreement, which gives us confidence in |
166 |
+ |
using FastSim for this study. |
167 |
+ |
|
168 |
+ |
The FastSim events are generated with different values of $m_0$ |
169 |
+ |
and $m_{1/2}$ in steps of 10 GeV. For each point in the |
170 |
+ |
$m_0$ vs. $m_{1/2}$ plane, we compute the expected number of |
171 |
+ |
events at NLO. We then also calculate an upper limit $N_{UL}$ |
172 |
+ |
using cl95cms at each point using the following inputs: |
173 |
+ |
\begin{itemize} |
174 |
+ |
\item Number of BG events = 1.40 $\pm$ 0.77 |
175 |
+ |
\item Luminosity uncertainty = 11\% |
176 |
+ |
\item The acceptance uncertainty is calculated at each point |
177 |
+ |
as the quadrature sum of |
178 |
+ |
\begin{itemize} |
179 |
+ |
\item The uncertainty due to JES for that point, as calculated |
180 |
+ |
using the method described in Section~\ref{sec:systematics} |
181 |
+ |
\item A 5\% uncertainty due to lepton efficiencies |
182 |
+ |
\item An uncertaity on the NLO cross-section obtained by varying the |
183 |
+ |
factorization and renormalization scale by a factor of two\cite{ref:sanjay}. |
184 |
+ |
\item The PDF uncertainty on the product of cross-section and acceptance |
185 |
+ |
calculated using the method of Reference~\cite{ref:pdf}. |
186 |
+ |
\end{itemize} |
187 |
+ |
\item We use the ``log-normal'' model for the nuisance parameters |
188 |
+ |
in cl95cms |
189 |
+ |
\end{itemize} |
190 |
+ |
|
191 |
+ |
An mSUGRA point is excluded if the resulting $N_{UL}$ is smaller |
192 |
+ |
than the expected number of events. Because of the quantization |
193 |
+ |
of the available MC points in the $m_0$ vs $m_{1/2}$ plane, the |
194 |
+ |
boundaries of the excluded region are also quantized. We smooth |
195 |
+ |
the boundaries using the method recommended by the SUSY |
196 |
+ |
group\cite{ref:smooth}. In addition, we show a limit |
197 |
+ |
curve based on the LO cross-section, as well as the |
198 |
+ |
``expected'' limit curve. The expected limit curve is |
199 |
+ |
calculated using the CLA function also available in cl95cms. |
200 |
+ |
Cross-section uncertainties due to variations of the factorization |
201 |
+ |
and renormalization scale are not included for the LO curve. |
202 |
+ |
The results are shown in Figure~\ref{fig:msugra} |
203 |
+ |
|
204 |
+ |
|
205 |
+ |
\begin{figure}[tbh] |
206 |
+ |
\begin{center} |
207 |
+ |
\includegraphics[width=\linewidth]{exclusion_noPDF.pdf} |
208 |
+ |
\caption{\label{fig:msugra}\protect Exclusion curves in the mSUGRA parameter space, |
209 |
+ |
assuming $\tan\beta=3$, sign of $\mu = +$ and $A_{0}=0$~GeVs. THIS IS STILL MISSING |
210 |
+ |
THE PDF UNCERTAINTIES. WE ALSO WANT TO IMPROVE THE SMOOTHING PROCEDURE.} |
211 |
+ |
\end{center} |
212 |
+ |
\end{figure} |
213 |
+ |
|
214 |
+ |
|
215 |
+ |
\subsubsection{Check of the nuisance parameter models} |
216 |
+ |
We repeat the procedure outlined above but changing the |
217 |
+ |
lognormal nuisance parameter model to a gaussian or |
218 |
+ |
gamma-function model. The results are shown in |
219 |
+ |
Figure~\ref{fig:nuisance}. (In this case, |
220 |
+ |
to avoid smoothing artifacts, we |
221 |
+ |
show the raw results, without smoothing). |
222 |
+ |
|
223 |
+ |
\begin{figure}[tbh] |
224 |
+ |
\begin{center} |
225 |
+ |
\includegraphics[width=0.5\linewidth]{nuissance.png} |
226 |
+ |
\caption{\label{fig:nuisance}\protect Exclusion curves in the |
227 |
+ |
mSUGRA parameter space, |
228 |
+ |
assuming $\tan\beta=3$, sign of $\mu = +$ and $A_{0}=0$~GeVs |
229 |
+ |
using different models for the nuisance parameters. |
230 |
+ |
PDF UNCERTAINTIES ARE NOT INCLUDED.} |
231 |
+ |
\end{center} |
232 |
+ |
\end{figure} |
233 |
+ |
|
234 |
+ |
We find that different assumptions on the PDFs for the nuisance |
235 |
+ |
parameters make very small differences to the set of excluded |
236 |
+ |
points. |
237 |
+ |
Following the recommendation of Reference~\cite{ref:cousins}, |
238 |
+ |
we use the lognormal nuisance parameter model as the default. |
239 |
+ |
|
240 |
+ |
|
241 |
+ |
\clearpage |
242 |
+ |
|
243 |
+ |
|
244 |
+ |
\subsubsection{Effect of signal contamination} |
245 |
+ |
\label{sec:contlimit} |
246 |
+ |
|
247 |
+ |
Signal contamination could affect the limit by inflating the |
248 |
+ |
background expectation. In our case we see no evidence of signal |
249 |
+ |
contamination, within statistics. |
250 |
+ |
The yields in the control regions |
251 |
+ |
$A$, $B$, and $C$ (Table~\ref{tab:datayield}) are just |
252 |
+ |
as expected in the SM, and the check |
253 |
+ |
of the $P_T(\ell \ell)$ method in the control region is |
254 |
+ |
also consistent with expectations (Table~\ref{tab:victory}). |
255 |
+ |
Since we have two data driven methods, with different |
256 |
+ |
signal contamination issues, giving consistent |
257 |
+ |
results that are in agreement with the SM, we |
258 |
+ |
argue for not making any correction to our procedure |
259 |
+ |
because of signal contamination. In some sense this would |
260 |
+ |
be equivalent to using the SM background prediction, and using |
261 |
+ |
the data driven methods as confirmations of that prediction. |
262 |
+ |
|
263 |
+ |
Nevertheless, here we explore the possible effect of |
264 |
+ |
signal contamination. The procedure suggested to us |
265 |
+ |
for the ABCD method is to modify the |
266 |
+ |
ABCD background prediction from $A_D \cdot C_D/B_D$ to |
267 |
+ |
$(A_D-A_S) \cdot (C_D-C_S) / (B_D - B_S)$, where the |
268 |
+ |
subscripts $D$ and $S$ refer to the number of observed data |
269 |
+ |
events and expected SUSY events, respectively, in a given region. |
270 |
+ |
We then recalculate $N_{UL}$ at each point using this modified |
271 |
+ |
ABCD background estimation. For simplicity we ignore |
272 |
+ |
information from the $P_T(\ell \ell)$ |
273 |
+ |
background estimation. This is conservative, since |
274 |
+ |
the $P_T(\ell\ell)$ background estimation happens to |
275 |
+ |
be numerically larger than the one from ABCD. |
276 |
+ |
|
277 |
+ |
Note, however, that in some cases this procedure is |
278 |
+ |
nonsensical. For example, take LM0 as a SUSY |
279 |
+ |
point. In region $C$ we have a SM prediction of 5.1 |
280 |
+ |
events and $C_D = 4$ in agreement with the Standard Model, |
281 |
+ |
see Table~\ref{tab:datayield}. From the LM0 Monte Carlo, |
282 |
+ |
we find $C_S = 8.6$ events. Thus, including information |
283 |
+ |
on $C_D$ and $C_S$ should {\bf strengthen} the limit, since there |
284 |
+ |
is clearly a deficit of events in the $C$ region in the |
285 |
+ |
LM0 hypothesis. Instead, we now get a negative ABCD |
286 |
+ |
BG prediction (which is nonsense, so we set it to zero), |
287 |
+ |
and therefore a weaker limit. |
288 |
+ |
|
289 |
+ |
|
290 |
+ |
|
291 |
+ |
|
292 |
+ |
\begin{figure}[tbh] |
293 |
+ |
\begin{center} |
294 |
+ |
\includegraphics[width=0.5\linewidth]{sigcont.png} |
295 |
+ |
\caption{\label{fig:sigcont}\protect Exclusion curves in the |
296 |
+ |
mSUGRA parameter space, |
297 |
+ |
assuming $\tan\beta=3$, sign of $\mu = +$ and $A_{0}=0$~GeVs |
298 |
+ |
with and without the effects of signal contamination. |
299 |
+ |
PDF UNCERTAINTIES ARE NOT INCLUDED.} |
300 |
+ |
\end{center} |
301 |
+ |
\end{figure} |
302 |
+ |
|
303 |
+ |
A comparison of the exclusion region with and without |
304 |
+ |
signal contamination is shown in Figure~\ref{fig:sigcont} |
305 |
+ |
(with no smoothing). The effect of signal contamination is |
306 |
+ |
small, of the same order as the quantization of the scan. |
307 |
+ |
|
308 |
+ |
|
309 |
+ |
\subsubsection{mSUGRA scans with different values of tan$\beta$} |
310 |
+ |
\label{sec:tanbetascan} |
311 |
+ |
|
312 |
+ |
For completeness, we also show the exclusion regions calculated |
313 |
+ |
using $\tan\beta = 10$ (Figure~\ref{fig:msugratb10}). |
314 |
+ |
|
315 |
+ |
\begin{figure}[tbh] |
316 |
+ |
\begin{center} |
317 |
+ |
\includegraphics[width=\linewidth]{exclusion_tanbeta10.pdf} |
318 |
+ |
\caption{\label{fig:msugratb10}\protect Exclusion curves in the mSUGRA parameter space, |
319 |
+ |
assuming $\tan\beta=10$, sign of $\mu = +$ and $A_{0}=0$~GeVs. THIS IS STILL MISSING |
320 |
+ |
THE PDF UNCERTAINTIES. WE ALSO WANT TO IMPROVE THE SMOOTHING PROCEDURE.} |
321 |
+ |
\end{center} |
322 |
+ |
\end{figure} |
323 |
+ |
|
324 |
+ |
|
325 |
+ |
|
326 |
+ |
|
327 |
+ |
|
328 |
+ |
|