1 cerizza 1.1 \subsection{Fit results}
2    
3     As previously mentioned, we first perform a fit to determine lifetimes and total yields. In Fig.~\ref{fig:proBsM}
4     and Fig.~\ref{fig:proBsCt} the fitted distributions of $M_B$ and $c\tau$ for the $B_s$ sample are shown assuming an
5     integrated luminosity of $3$ $pb^{-1}$. The plots show the total contribution from signal and background components
6     (solid blue line) and the different components. Table 12 summarizes the fitted yields and lifetime for the sample considered.
7    
8     \begin{table}[htbp]
9     \centering
10     \vspace{0.3cm}
11     \begin{tabular}{cc}
12     \hline\hline
13     Components & $B_s\rightarrow J/ \psi \phi$ \\
14     \hline
15     Signal & $179 \pm 17$ \\
16     $\lambda$ ($\mu$m) & $424\pm 41$\\
17     Generated $\lambda$ ($\mu$m) & $423$\\
18     B background & $244\pm 63$ \\
19     Prompt $J/ \psi$ & $664\pm 64$ \\
20     Bias & $-1.29 \pm 0.43$ \\
21     Scaling factor & $1.06 \pm 0.44$ \\
22     \hline\hline
23     \end{tabular}
24     \caption{Summary of the ML fit on the MC dataset.}
25     \end{table}
26    
27     \begin{figure}[!h!t]
28     \vspace{0.5cm}
29     \begin{minipage}[b]{0.5\linewidth}
30     \centering
31     \includegraphics[scale=0.4]{figure/proj_BsM.eps}
32     \caption{Projection of the fit onto the $B_s$ invariant mass variable (solid blue) with the different components:
33     signal (dashed red), B background (dashed blue) and prompt $J/ \psi$ background (dashed green).}
34     \label{fig:proBsM}
35     \end{minipage}
36     \hspace{0.5cm}
37     \begin{minipage}[b]{0.5\linewidth}
38     \centering
39     \includegraphics[scale=0.4]{figure/proj_ctauL.eps}
40     \caption{Projection of the fit onto the $B_s$ proper decay length variable (solid blue) with the different components:
41     signal (dashed red), B background (dashed blue) and prompt $J/ \psi$ background (dashed green).}
42     \label{fig:proBsCt}
43     \end{minipage}
44     \end{figure}
45    
46     \clearpage